Adroit Edge Gateway software on a monitor and laptop, linking offshore, refinery, mining, water, renewable energy, manufacturing and agricultural operations

Connect Your Industrial World.
Put Your Data to Work

Meet Adroit Edge Gateway – the intelligent connection between your industrial world and the digital future.

Connecting intelligence. Empowering decisions. Enabling the future.

Designed to bridge the gap between operational technology and enterprise systems, Adroit Edge Gateway enables information to be collected, processed and communicated closer to where it is generated. By bringing intelligence to the edge, it helps organisations improve visibility, optimise performance and make faster, more informed decisions.

At its core, the gateway transforms raw industrial data into meaningful, contextualised information, ready to be used by cloud platforms, analytics tools and business applications. It supports connectivity to PLCs, RTUs, SCADA systems and other industrial data sources, with integration options including OPC UA, MQTT, REST and cloud services such as Microsoft Azure and AWS.

Its flexible architecture supports both standalone deployments and enterprise gateway configurations, allowing organisations to modernise existing infrastructure and expand their digital capabilities without necessarily replacing established systems.

A more connected, informed and responsive operation, where operational data becomes a valuable business asset.

Want to Dive Deeper?

Adroit Edge Gateway Overview

Adroit Edge Gateway Quick Start Guide

Core Capabilities

Adroit Edge Gateway acting as an OPC UA Server between PLCs, drives, robots, instruments and HMIs on one side and dashboards, cloud, ERP and databases on the other

Integrated OPC UA Server

OPC UA

The Adroit Edge Gateway also functions as an integrated OPC UA Server, enabling secure, standardised access to industrial data from connected devices, controllers and systems. By exposing this data through the OPC UA protocol, it provides seamless interoperability with third-party applications, platforms and enterprise systems, simplifying data exchange and extending connectivity across the industrial environment.

Adroit Edge Gateway feeding a stack of edge publishers for connectivity, data exchange, storage and cloud delivery

Edge Services & Data Publishers

Edge Publishers

The Adroit Edge Gateway supports a flexible suite of Edge Publishers and Microservices, each designed to provide specialised data orchestration, protocol encapsulation and endpoint connectivity. These modular services enable industrial data to be efficiently managed, transformed and distributed between connected devices, applications and platforms. By supporting diverse protocols and communication endpoints, they provide a flexible and scalable integration framework, simplifying connectivity and enabling seamless data exchange across the industrial and enterprise landscape.

Features and Benefits

Connect. Contextualise. Securely Publish. Scale.

Turn industrial signals into usable, business-ready information with software that connects established OT sources to enterprise and supported cloud platforms.

Connect Industrial Systems

Access operational values through Adroit Agent Server(s) and suitable industrial communication drivers. Existing Adroit SCADA sources or direct device acquisition can be used according to the deployment mode.

Benefit: Bring diverse plant equipment and operational systems into a more consistent integration workflow.

Contextualise Data at the Edge

Select, transform and enrich acquired values with meaningful operational context, such as equipment, asset, product, process, production or location, before publishing. Exact enrichment options depend on the current implementation.

Benefit: Deliver understandable information, not an uncontrolled stream of raw PLC values.

Securely Publish Selected Information

Configure supported Microservice Connections and Publishers for selected downstream interfaces, including MQTT, OPC UA and HTTP where available. Cloud-specific destinations may include Adroit Cloud, Microsoft Azure and AWS, subject to current connectors, licensing and configuration.

Benefit: Control what information leaves the operational environment and where it is delivered.

Flexible Software Deployment

Use Gateway Mode to integrate with suitable existing Adroit Agent Servers, or Stand-Alone Mode to collect device data through a locally configured Agent Server.

Benefit: Match the integration approach to existing infrastructure, from a single site to broader deployments.

A control room engineer reviewing process graphics and live data on two monitors

Connect suitable remote Adroit Agent Servers or clusters as Datasources in Gateway Mode and select the required Agent values and properties.

Benefit: Reuse operational information collected by an existing Adroit SCADA deployment.

See Adroit Edge Gateway in Action

Explore data acquisition, Datasource configuration, publishing workflows and software diagnostics with an Adroit specialist.

Technology Stack & Data Flow

From Industrial Data to Business-Ready Information

Adroit Edge Gateway connects operational data with the systems that need it. Built on proven Adroit Agent Server technology, the software acquires, processes and contextualises data from PLCs, machines and existing SCADA environments. Configurable Microservices then securely publish selected information to supported industrial, enterprise and cloud platforms.

The result is a flexible, scalable integration layer that transforms raw operational values into meaningful information for reporting, analytics and better business decisions.

Adroit Edge Gateway technology stack: operational technology (PLCs, RTUs, HMIs, plant and equipment) feeding the Edge Gateway's drivers, Agents, Smart Data Services, microservices and edge configuration, which securely publish to Adroit Cloud, AWS, HTTP, OPC UA, MQTT and Azure for dashboards, reports, data analytics and AI analytics

Data Flow

Two Ways to Deploy: Gateway Mode and Stand-Alone Mode

Reuse existing Adroit Agent Servers in Gateway Mode, or collect data directly from devices in Stand-Alone Mode.

Adroit Gateway Mode: Adroit Edge publishing to enterprise systems, cloud service providers, MQTT brokers and API connections, fed by an Adroit stand-alone system and an active cluster, each connected to PLCs and production lines

Gateway Mode

Reuse existing Adroit Agent Servers

Adroit Edge Gateway Mode provides a centralised layer for consolidating and distributing data from multiple Adroit SCADA systems and other sources. It supports two primary approaches:

  • OPC UA Gateway

    Acts as a central OPC UA server, collecting selected data from multiple Adroit systems and exposing it through a unified interface to OPC UA-compliant clients and third-party applications.

  • Microservice Gateway

    It collects information from multiple Adroit systems and other supported sources, consolidates and contextualises the data before streaming unified datasets to configured endpoints, such as cloud platforms, databases, data lakes and enterprise applications.

Gateway Mode uses suitable existing Adroit Agent Servers as remote Datasources or a local Adroit datasource. Gateway then acts as a centralised gateway and publisher.

Adroit Stand-Alone Mode: Adroit Edge collecting data directly from a PLC on a bottling line and publishing to enterprise systems, cloud service providers, MQTT brokers and API connections

Stand-Alone Mode

Direct industrial acquisition through local Agent technology

  1. Supported PLCs / RTUs / other industrial devices
  2. Local Adroit Agent Server drivers and configured Agents
  3. Edge Gateway Datasource
  4. Contextualisation and configured Microservice Publisher
  5. Authorised receiving application or system

In Stand-Alone Mode, the included local Adroit Agent Server is configured with the required device drivers, Agents and scanning. Edge Gateway then selects those Agent values as Datasources for its configured Microservices. The solution uses Adroit SCADA technology but is not a conventional operator HMI.

Adroit Edge in a DMZ between an OT firewall and an IT firewall: Adroit SCADA local and remote sites and other data sources on the OT side, an industrial Edge Mini PC running Windows IoT with OPC UA and Microservice gateways in the DMZ, and cloud platforms, enterprise databases, analytics and business applications on the IT side

Deployment

DMZ Deployment - Security Benefits

Deploying Adroit Edge within a DMZ creates a secure separation between the OT and corporate IT networks. Acting as a controlled data gateway, it eliminates the need for direct external access to SCADA systems.

Separate firewalls regulate communication on either side of the DMZ, allowing only authorised protocols, ports and destinations. This reduces network exposure, limits potential attack paths and enables secure data sharing with enterprise and cloud platforms while keeping critical OT infrastructure protected.

Where the Gateway Can Be Positioned

Within the OT network

Close to the SCADA system or industrial data sources.

Within the DMZ

As a controlled intermediary between OT and IT/cloud networks.

Within the IT network

Where the required data sources and security architecture permit.

This flexibility allows each deployment to be tailored to the customer's existing infrastructure, cybersecurity policies and operational requirements, without being locked into a specific hardware platform.

A Closer Look at Adroit Edge Gateway

Explore the software behind smarter industrial data integration. See how Adroit Edge Gateway simplifies data configuration, manages publishing services and provides visibility into live operational values, system events and diagnostics.

Adroit Datasources

The Datasources tree lists the connected Adroit Agent Servers and their Agents. Existing Agent Server values are added as Datasources, then browsed and selected for publishing.

Configure Microservice Publishers

MQTT publishing and topic settings define the configured publishing destination, the conditions under which a publisher runs and the interval or trigger that sends each update.

Substitutions and Payload

Each configured publisher has a JSON payload structure, with data-element substitutions mapping Agent values into the message that is sent.

Monitor Services and Data Publishers

Get a clear view of licence, service and Microservice status from one interface. Monitor publisher activity, check connection status and quickly identify issues that need attention.

Monitor Live Data with Watches

View live Agent values and trends directly within the software, helping technical teams verify data connectivity and monitor changing operational conditions.

Events and Logs

Event records and logging tools help investigate a publisher or connection issue and trace what happened, and when.

Build the Right Edge Data Architecture

Tell us about your existing SCADA, PLCs, connected devices, Agent Servers, required data points and integration destinations.

Questions often asked.

Adroit Edge is a software-based gateway, not a proprietary hardware appliance. It is designed to run on standard Windows-based computing platforms, providing flexibility in how and where it is deployed. For industrial environments, we typically recommend running Adroit Edge on an industrial-grade Edge Mini PC with Windows IoT operating system. This provides a dedicated, reliable platform suited to industrial operating conditions while retaining the flexibility and scalability of a software solution.

Yes. The Adroit Edge Gateway is specifically suited to deployment within an industrial Demilitarised Zone (DMZ), providing a controlled boundary between the operational technology (OT) network and external IT or cloud environments. By positioning the gateway in the DMZ, data can be securely collected from the SCADA system or other OT sources and forwarded to designated destinations without requiring direct external access to the SCADA network. Communication can be configured using controlled firewall rules, typically with outbound connections to approved endpoints. This architecture helps maintain network segmentation while enabling secure industrial data integration.

Because Adroit Edge is software-based, it offers considerable flexibility in terms of deployment architecture. It can be installed on a dedicated industrial Edge Mini PC, an existing Windows-based server, or another suitable Windows environment, depending on the project's requirements.

Adroit Edge supports different communication architectures depending on integration and security requirements. OPC UA provides bidirectional client/server communication, allowing systems to both read and exchange data. While flexible and widely used for internal network integration, it typically requires defined network access and open communication ports to the OPC UA server, making firewall configuration important. Publisher mode, on the other hand, uses an outbound-only communication model. Data is published from the Edge Gateway to configured endpoints or brokers, with no inbound ports required for external connections. This makes it particularly suitable for DMZ deployments and cloud integration, as it minimises network exposure while allowing operational data to be securely distributed to external platforms. The gateway can be positioned within the OT network, within the DMZ or within the IT network. This flexibility allows each deployment to be tailored to the customer's existing infrastructure, cybersecurity policies and operational requirements, without being locked into a specific hardware platform.

Yes. In Gateway Mode, the software can use suitable existing Adroit Agent Servers or clusters as Datasources, subject to connection, installation and version prerequisites. The Quick Start Guide references Adroit SCADA 10 or later.

Yes. Stand-Alone Mode uses a local Adroit Agent Server and its industrial drivers/Agents to collect data from supported PLCs and other devices; an existing complete Adroit SCADA HMI installation is not a prerequisite.

No. Adroit Cloud is a separate product. Edge Gateway can publish to supported industrial, enterprise and cloud destinations according to its configured Microservices and licence.

Input connectivity is provided by the supported Adroit industrial driver and Agent Server technology. Source examples include Mitsubishi Electric, Siemens, Allen-Bradley, Modbus, BACnet, SNMP, OPC / OPC UA, OLEDB and DNP3; availability and specific driver behaviour must be confirmed for the proposed deployment.

Published interfaces depend on available Microservices and the release/licence. These include MQTT, OPC UA and HTTP, and cloud-facing integrations such as Adroit Cloud, Microsoft Azure and AWS. Input protocols and outbound publishing protocols are different categories and are not interchangeable.

Yes. Technical users can use Dashboard, Watches, Events and Logs to review supported live values, service state and errors. These are gateway-configuration and diagnostic tools; Edge Gateway does not include a full enterprise BI/dashboard platform.

Through a security design appropriate to the OT/IT boundary, including network zoning, permissions, authentication, supported encryption and destination-specific controls. Security should be confirmed by reviewing the actual architecture and protocol configuration.

Provide existing Adroit version and Agent Server details (if any), source PLCs/devices, required tags/data points, site count, intended data context, publishing destinations, desired update frequency, network/security constraints and preferred deployment mode.

Connect More of Your Industrial Data

Speak to Adroit Technologies about operational connectivity, Gateway deployment and the right path from plant data to practical integration.