<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>FX5-4DA</title>
	<atom:link href="https://adroitscada.com/product-category/plc-expansion-modules/fx5-4da/feed/" rel="self" type="application/rss+xml" />
	<link>https://adroitscada.com</link>
	<description>Operational Technology Focused Products</description>
	<lastBuildDate>Tue, 28 Jul 2026 04:38:30 +0000</lastBuildDate>
	<language>en-ZA</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1</generator>

<image>
	<url>https://adroitscada.com/wp-content/uploads/2021/06/cropped-Logo-32x32.png</url>
	<title>FX5-4DA</title>
	<link>https://adroitscada.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>FX5-4DA</title>
		<link>https://adroitscada.com/product/fx5-4da/</link>
					<comments>https://adroitscada.com/product/fx5-4da/#respond</comments>
		
		<dc:creator><![CDATA[samanthab]]></dc:creator>
		<pubDate>Thu, 07 Aug 2025 13:16:26 +0000</pubDate>
				<guid isPermaLink="false">https://adroitscada.com/?post_type=product&#038;p=43226</guid>

					<description><![CDATA[<ul>
 	<li><strong>Important Notice:</strong>
<ul>
 	<li>Stock is subject to availability and may vary due to dynamic stock levels.</li>
 	<li>Mitsubishi Electric Factory Automation Hardware Products are <strong>for collection only</strong>.
<ul>
 	<li>You can arrange for your courier to collect the item or opt for self-collection.</li>
</ul>
</li>
 	<li>If a product is out of stock, it will be placed on backorder.</li>
</ul>
<strong>Shipping</strong>: NOT included</li>
</ul>]]></description>
										<content:encoded><![CDATA[<h2 data-start="124" data-end="204"><strong data-start="127" data-end="204">FX5-4DA – Mitsubishi Electric Analog Output Expansion Module (4 Channels)</strong></h2>
<p data-start="206" data-end="562">The <a href="https://emea.mitsubishielectric.com/fa/products/cnt/plc/plcf/analog-control-module/fx5-4da.html" target="_blank" rel="noopener">FX5-4DA</a> is a 4-channel analog output expansion module designed for the Mitsubishi Electric FX5U and FX5UC PLCs. It allows precise analog voltage or current output signals, making it ideal for applications requiring fine control of actuators, valves, or variable speed drives. This module supports both voltage (0–10V) and current (4–20mA) output types.</p>
<p data-start="564" data-end="705">It is used in industries requiring accurate signal transmission for automation systems, such as HVAC, chemical processing, and fluid control.</p>
<hr data-start="707" data-end="710" />
<h3 data-start="712" data-end="728">Key Features</h3>
<ul data-start="730" data-end="1054">
<li data-start="730" data-end="758">
<p data-start="732" data-end="758">4 analog output channels</p>
</li>
<li data-start="759" data-end="795">
<p data-start="761" data-end="795">Output types: 0–10V DC or 4–20mA</p>
</li>
<li data-start="796" data-end="830">
<p data-start="798" data-end="830">High-resolution D/A conversion</p>
</li>
<li data-start="831" data-end="891">
<p data-start="833" data-end="891">Suitable for process control and analog actuator control</p>
</li>
<li data-start="892" data-end="930">
<p data-start="894" data-end="930">Connects to FX5U/FX5UC series PLCs</p>
</li>
<li data-start="931" data-end="969">
<p data-start="933" data-end="969">Compatible with GX Works3 software</p>
</li>
<li data-start="970" data-end="1004">
<p data-start="972" data-end="1004">Compact and DIN rail mountable</p>
</li>
<li data-start="1005" data-end="1054">
<p data-start="1007" data-end="1054">Stable performance in industrial environments</p>
</li>
</ul>
<h3 data-start="1061" data-end="1089">Technical Specifications</h3>
<div class="_tableContainer_16hzy_1">
<div class="_tableWrapper_16hzy_14 group flex w-fit flex-col-reverse" tabindex="-1">
<table class="w-fit min-w-(--thread-content-width)" data-start="1091" data-end="2132">
<thead data-start="1091" data-end="1176">
<tr data-start="1091" data-end="1176">
<th data-start="1091" data-end="1118" data-col-size="sm">Specification</th>
<th data-start="1118" data-end="1176" data-col-size="sm">Value</th>
</tr>
</thead>
<tbody data-start="1264" data-end="2132">
<tr data-start="1264" data-end="1350">
<td data-start="1264" data-end="1291" data-col-size="sm">Model Number</td>
<td data-col-size="sm" data-start="1291" data-end="1350">FX5-4DA</td>
</tr>
<tr data-start="1351" data-end="1437">
<td data-start="1351" data-end="1378" data-col-size="sm">Analog Outputs</td>
<td data-col-size="sm" data-start="1378" data-end="1437">4</td>
</tr>
<tr data-start="1438" data-end="1524">
<td data-start="1438" data-end="1465" data-col-size="sm">Output Type</td>
<td data-col-size="sm" data-start="1465" data-end="1524">Voltage (0–10V DC), Current (4–20mA)</td>
</tr>
<tr data-start="1525" data-end="1611">
<td data-start="1525" data-end="1552" data-col-size="sm">Resolution</td>
<td data-col-size="sm" data-start="1552" data-end="1611">12-bit</td>
</tr>
<tr data-start="1612" data-end="1698">
<td data-start="1612" data-end="1639" data-col-size="sm">Accuracy</td>
<td data-col-size="sm" data-start="1639" data-end="1698">±0.5% full scale</td>
</tr>
<tr data-start="1699" data-end="1785">
<td data-start="1699" data-end="1726" data-col-size="sm">Power Supply</td>
<td data-col-size="sm" data-start="1726" data-end="1785">Supplied from base unit</td>
</tr>
<tr data-start="1786" data-end="1871">
<td data-start="1786" data-end="1813" data-col-size="sm">Interface</td>
<td data-col-size="sm" data-start="1813" data-end="1871">FX5U/FX5UC PLC bus</td>
</tr>
<tr data-start="1872" data-end="1958">
<td data-start="1872" data-end="1899" data-col-size="sm">Mounting</td>
<td data-col-size="sm" data-start="1899" data-end="1958">DIN Rail</td>
</tr>
<tr data-start="1959" data-end="2045">
<td data-start="1959" data-end="1986" data-col-size="sm">Programming Software</td>
<td data-col-size="sm" data-start="1986" data-end="2045">GX Works3</td>
</tr>
<tr data-start="2046" data-end="2132">
<td data-start="2046" data-end="2073" data-col-size="sm">Compatible PLCs</td>
<td data-col-size="sm" data-start="2073" data-end="2132">FX5U, FX5UC</td>
</tr>
</tbody>
</table>
<div class="sticky end-(--thread-content-margin) h-0 self-end select-none">
<div class="absolute end-0 flex items-end"></div>
</div>
</div>
</div>
<h3 data-start="2139" data-end="2155">Applications</h3>
<ul data-start="2157" data-end="2364">
<li data-start="2157" data-end="2184">
<p data-start="2159" data-end="2184">Analog actuator control</p>
</li>
<li data-start="2185" data-end="2221">
<p data-start="2187" data-end="2221">Variable frequency drive control</p>
</li>
<li data-start="2222" data-end="2238">
<p data-start="2224" data-end="2238">HVAC systems</p>
</li>
<li data-start="2239" data-end="2277">
<p data-start="2241" data-end="2277">Chemical dosing and mixing systems</p>
</li>
<li data-start="2278" data-end="2310">
<p data-start="2280" data-end="2310">Fluid control and monitoring</p>
</li>
<li data-start="2311" data-end="2364">
<p data-start="2313" data-end="2364">Process automation requiring analog signal output</p>
</li>
</ul>
<h3 data-start="2371" data-end="2391">Related Products</h3>
<ul data-start="2393" data-end="2539">
<li data-start="2393" data-end="2440">
<p data-start="2395" data-end="2440">FX5U-32MR/DS – Mitsubishi Electric FX5U PLC</p>
</li>
<li data-start="2441" data-end="2487">
<p data-start="2443" data-end="2487">FX5-4AD-TC-ADP – Thermocouple input module</p>
</li>
<li data-start="2488" data-end="2539">
<p data-start="2490" data-end="2539">GX Works3 – Programming software for FX5 series</p>